PLC(Planar Lightwave Circuit) Splitter
(1X2/1×4/1X8/1X16/1X32/1X642X4/2X8/2X16/2X32/2×64)
Features | Applications |
Low insertion loss and high uniform
Low polarization relevant Redundant reliability |
FTTX application
CATV network Passive Optical Network(PON) |
Performance Specifications:
1XN Series:
Type | 1×2 | 1×4 | 1×8 | 1×16 | 1×32 | 1×64 | |
Operating wavelength(nm) | 1260-1650 | ||||||
Insertion loss (dB)1,2 | Typical value | 3.6 | 7.2 | 10.5 | 13.5 | 16.5 | 19.5 |
Maximum value | 4.0 | 7.5 | 11.0 | 14.0 | 17.5 | 21.0 | |
Loss uniformity (dB)1,2 | Maximum value | 0.5 | 0.6 | 0.8 | 1.2 | 1.7 | 2.5 |
Polarization dependent loss (dB)1,2 | Maximum value | 0.15 | |||||
Wavelength dependent loss (dB) | Maximum value | 1.0 | |||||
Return loss (dB)1,3 | Minimum value | ≥50 | |||||
Directivity (dB)1,3 | Minimum value | ≥55 | |||||
Operating temperature (℃) | -20 to 85 | ||||||
Storage temperature (℃) | -40 to 85 | ||||||
Optical fiber type | SMF-28 Or the customer require | ||||||
Optical fiber length (m) | 1.2 |
2XN Series:
Type | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 | |
Operating wavelength(nm) | 1260-1650 | |||||
Insertion loss (dB)1,2 | Typical value | 7.5 | 11.2 | 14.2 | 18.0 | 21.5 |
Maximum value | 7.8 | 11.5 | 14.6 | 18.5 | 22 | |
Loss uniformity (dB)1,2 | Maximum value | 0.8 | 1.5 | 2.0 | 2.5 | 3.0 |
Polarization dependent loss (dB)1,2 | Maximum value | 0.4 | ||||
Wavelength dependent loss (dB) | Maximum value | 1.0 | ||||
Return loss (dB)1,3 | Minimum value | ≥50 | ||||
Directivity (dB)1,3 | Minimum value | ≥55 | ||||
Operating temperature (℃) | -20 to 85 | |||||
Storage temperature (℃) | -40 to 85 | |||||
Optical fiber type | SMF-28 Or the customer require | |||||
Optical fiber length (m) | 1.2 |
Performance Specifications:
- all measurement at room temperature,
- specification exclude connector loss
- exclude connector
Package Drawing (SS.Tube)
S.S.Tube Dimensions
PLC Type | 1×2 | 1×4 | 2×4 | 1×8 | 2×8 | 1×16 | 2×16 | 1×32 | 2×32 | 1×64 |
SS tube1 (mm) |
4x4x40 | 4x4x40 | 4x4x55 | 4x4x40 | 4x4x55 | 4x7x50 | 4x7x60 | 4x7x50 | 4x7x50 | 4x12x60 |
SS tube2 (mm) |
4x12x60 | 6x20x80 |
Box Type Dimensions
PLC Type | 1×2 | 1×4 | 2×4 | 1×8 | 2×8 | 1×16 | 2×16 | 1×32 | 2×32 | 1×64 | 2×64 |
Box Size (mm) |
100*80*10 | 120*80*18 | 142*102*14.5 | 141*115*18 |
Package Drawing (Box Type)
Bare Fiber with S.S.Tube,No-connector Fiber with ¢0.9 Loose tube / ¢2 cable /¢3 cable or Connector
LGX Model 19Inch Rack
Ordering Information:
Input Channel Number | Package
Type |
Input Optical
Fiber Type |
Output Channel Number | Output Optical
Fiber Type |
Connector Type(In/Out) |
1-1 channel
2-2 channel |
S1=
S.S Tube G1 S2= S.S Tube G2 S3=S.S Tube2 B1= Box1 100*80*10 B2=Box 2 120*80*18 B3=Box 3 142*102*14.5 B4=Box 4 141*115*18 |
B-250um bare optical fiber
L-900um loose tube T-900um tight buffer 2=2mm cable 3=3mm cable
|
02-2 Channel
04-4 channel 08-8 channel 16-16 channel 32–32 Channel 64-64 channel |
0-250um Bare fiber
L-900umloose tube 2=2mm cable 3=3mm cable
|
0-none